Designed for Fitzpatrick skin types I–VI with wavelength and parameter selection appropriate to each client.


















Health Canada License: 114257
DioLaz Health Canada Licensed Hair Removal Laser Machine 3 Wavelengths
Short Description
Pairs well with
Free Indoor Shipping. Ships within 2 business days.

DioLaz Health Canada Licensed Hair Removal Laser Machine 3 Wavelengths

Want to Learn More?
Click below to Discover the DioLaz Diode Laser
View all Technical Details
Needs more information? Contact: Sales@diolaz.com
Want to Learn More?
Explore the product brochure or review DioLaz clinical education for the triple-wavelength diode laser platform.

Active licence listed in Health Canada’s MDALL database. Licence holder (manufacturer): DioLaz Canada Inc.
Built for Efficient, Versatile Hair-Removal Workflows
One system combines multi-wavelength delivery, high-speed coverage, precision treatment modes and integrated cooling.
Up to 100 J/cm², up to 10 Hz and a 12 × 24 mm spot support efficient treatment of larger areas.
Sapphire contact cooling draws heat from the skin before, during and after laser delivery.
Skin-type presets, emergency controls and a treatment-room interlock support professional operation.
Three Wavelengths, One Platform
Combined wavelength delivery supports treatment planning across different follicle depths, hair characteristics and skin types.
Targets more superficial follicles and finer hair, commonly used for lighter skin tones.
Balances penetration and melanin absorption for a broad range of hair and skin combinations.
Lower melanin absorption supports darker skin types and treatment of coarse, deeply rooted hair.
Final settings must follow professional training, client assessment and the DioLaz User Manual.
SHR for Coverage. HR for Precision.
Choose the delivery method that best matches the treatment area and desired level of operator control.
A continuous gliding approach for larger areas such as the back, abdomen, thighs and legs. Controlled passes build heat gradually across the treatment zone.
Static pulse placement for smaller, contoured or detail-focused areas such as the underarms, bikini line and upper lip.
Switch between SHR and HR within the same session to combine broad coverage with detailed finishing.
Precision, Cooling and Safety in One System
Key design features support access to smaller areas, continuous epidermal cooling and treatment-room safety controls.

The bent crystal tip extends access to small or contoured areas, including around the lips, ears, nostrils, fingers and toes.

The sapphire contact tip provides continuous epidermal cooling to approximately −32°C before, during and after laser delivery.

The interlock can automatically disable laser emission if treatment-room access is interrupted during a procedure.
Detailed Technical Information
Open only the section you need. The main shopping page stays concise while important technical and regulatory information remains available.
Health Canada Licence Details
Operating Modes and Treatment Workflow
SHR Mode: The handpiece remains in continuous motion over larger treatment areas. Protocols may use repeated horizontal and vertical passes until the treatment endpoint defined in training and the User Manual is reached.
HR Mode: The system delivers a concentrated pulse with each trigger press for smaller or contoured areas. Pulse overlap, pass count and energy settings must follow the approved protocol and client assessment.
SHR and HR can be combined within one session to move from broad coverage to detailed finishing without changing platforms.
Performance, Pulse Control and Cooling
- Fluence up to 100 J/cm².
- Repetition rate up to 10 Hz.
- 12 × 24 mm treatment spot for efficient area coverage.
- Adjustable pulse durations from 5 ms to 300 ms.
- Optimized beam delivery with a uniform top-hat profile.
- Dual-circuit cooling with sapphire contact cooling to approximately −32°C.
The cooling system is designed to draw heat from the epidermis throughout treatment and support a more comfortable client experience.
Precision Tip and Safety Engineering
Precision tip: The bent crystal light guide is designed for small and difficult-to-reach treatment zones, allowing more focused delivery in contoured areas.
Door interlock: The treatment-room interlock can interrupt laser emission when the connected door circuit is opened, adding an engineered layer of protection for the operator, patient and surrounding environment.
Additional controls: Skin-type presets, emergency controls and professional operating protocols support safe system use.
Contact the DioLaz sales team for product, demo and purchasing questions.
For professional use only. Contraindications, precautions and treatment parameters must be reviewed in the DioLaz User Manual before clinical use.
If you have any questions, you are always welcome to contact us. We'll get back to you as soon as possible.
-
Shipping Information
At DioLaz Canada Inc., every order is handled with exceptional precision and care, ensuring your premium medical and aesthetic products reach you safely, securely, and promptly.
-
Customer Support
DioLaz Canada Inc. stands confidently behind the quality and reliability of our Medical and Aesthetic Devices. Our comprehensive warranty policy is carefully crafted to provide peace of mind to our valued customers.
-
Contact Us
customersupport@diolaz.com
Other Collections
Dr. Pen A20 Microneedling System
DioLaz Health Canada Licensed Fractional CO2 Laser Skin Resurfacing Machine
DioLaz Health Canada Licensed Hair Removal Laser Machine 3 Wavelengths