Up to 1,200 W of peak optical power supports consistent fluence at higher repetition rates.

















DioLaz Health Canada Licensed Hair Removal Laser Machine 3 Wavelengths
Short Description
Pairs well with
Ships within 1-3 business days.

DioLaz Health Canada Licensed Hair Removal Laser Machine 3 Wavelengths
Product details
Description
Triple-Wavelength Performance, Designed for Professional Clinics
A 755 / 808 / 1064 nm diode platform that combines high optical output, rapid area coverage, sapphire contact cooling and precision treatment modes.
Active licence listed in Health Canada’s MDALL database. Licence holder (manufacturer): DioLaz Canada Inc.
Power, Speed and Control in One Platform
The DioLaz system is designed to maintain treatment efficiency across both large body areas and detail-focused zones without sacrificing parameter control.
A 12 × 24 mm spot and repetition rates up to 10 Hz support faster treatment of larger areas.
Adjustable pulse durations from 5 ms to 300 ms and a uniform top-hat beam support tailored delivery.
Dual-circuit cooling draws heat from the epidermis before, during and after laser delivery.
Choose the Handpiece Workflow That Fits Your Clinic
The product page offers two handpiece configurations. Select the correct model before ordering; the configurations are not included together.

Traditional Handpiece
A familiar, streamlined treatment interface operated from the main console.

Built-in Touch Screen Handpiece
Adds a dedicated display directly on the handpiece for at-a-glance workflow support.
Images illustrate the available configurations. Only the handpiece and model selected on the product page are supplied.
Three Wavelengths, One Platform
Combined wavelength delivery supports treatment planning across follicle depths, hair characteristics and Fitzpatrick skin types I–VI.
Supports finer hair and more superficial follicles, commonly used for lighter skin tones.
Balances penetration and melanin absorption for a broad range of hair and skin combinations.
Lower melanin absorption supports darker skin types and coarse, deeply rooted hair.
Final settings must follow professional training, client assessment and the DioLaz User Manual.

SHR for Coverage. HR for Precision.
Move between broad-area work and detailed finishing without changing platforms.
Continuous gliding for larger areas such as the back, abdomen, thighs and legs. Repeated passes build heat gradually across the treatment zone.
Static pulse placement for smaller or contoured areas such as the underarms, bikini line and upper lip.
Switch between SHR and HR within the same session to combine broad coverage with detailed finishing.
Precision, Cooling and Engineered Safety
Purpose-built accessories and safety controls support detailed treatment, epidermal cooling and professional treatment-room operation.

The bent crystal tip extends access to small or contoured areas, including around the lips, ears, nostrils, fingers and toes.

The sapphire contact window provides continuous epidermal cooling to approximately −32°C before, during and after laser delivery.

The interlock can automatically disable laser emission if treatment-room access is interrupted during a procedure.
Detailed Technical Information
Open only the section you need. The shopping page stays visually concise while important technical and regulatory information remains available.
Health Canada Licence Details
Performance, Pulse Control and Cooling
- Peak optical output up to 1,200 W.
- Fluence from 1 to 100 J/cm².
- Repetition rate up to 10 Hz.
- 12 × 24 mm treatment spot.
- Adjustable pulse durations from 5 ms to 300 ms.
- Uniform top-hat beam profile.
- Dual-circuit cooling with sapphire contact cooling to approximately −32°C.
The cooling system is designed to draw heat from the epidermis throughout treatment and support a more comfortable client experience.
Operating Modes and Treatment Workflow
SHR Mode: The handpiece remains in continuous motion over larger treatment areas. Protocols may use repeated horizontal and vertical passes until the treatment endpoint defined in training and the User Manual is reached.
HR Mode: The system delivers a concentrated pulse with each trigger press for smaller or contoured areas. Pulse overlap, pass count and energy settings must follow the approved protocol and client assessment.
SHR and HR can be combined within one session to move from broad coverage to detailed finishing without changing platforms.
Precision Tip and Safety Engineering
Precision tip: The bent crystal light guide is designed for small and difficult-to-reach treatment zones, allowing more focused delivery in contoured areas.
Door interlock: The treatment-room interlock can interrupt laser emission when the connected door circuit is opened, adding an engineered layer of protection for the operator, patient and surrounding environment.
Additional controls: Skin-type presets, emergency controls and professional operating protocols support safe system use.
Contact the DioLaz sales team for product, demo and purchasing questions.
For professional use only. Contraindications, precautions and treatment parameters must be reviewed in the DioLaz User Manual before clinical use.
If you have any questions, you are always welcome to contact us. We'll get back to you as soon as possible.
-
Shipping Information
At DioLaz Canada Inc., every order is handled with exceptional precision and care, ensuring your premium medical and aesthetic products reach you safely, securely, and promptly.
-
Customer Support
DioLaz Canada Inc. stands confidently behind the quality and reliability of our Medical and Aesthetic Devices. Our comprehensive warranty policy is carefully crafted to provide peace of mind to our valued customers.
-
Contact Us
customersupport@diolaz.com